← Compton Castle
Spill evidence · Friends of the River Teign
Compton Castle
Combined sewer overflow · SBB00301 · feeds COMPTON AND MARLDON STW
Wet weather
The discharge
- Spill day
- Saturday, 2 May 2026
- Started
- 2 May 2026, 13:50
- Ended
- 2 May 2026, 15:14
- Duration
- 1 hour 24 minutes
- Receiving water
- Aller Brook
- Parish
- Marldon
Rainfall evidence
Daily rainfall at the matched gauge (Torbay Compton) for the spill day and the days before. A spill is dry when every day in the window is ≤ 0.25 mm.
1-day window: Wet weather3-day window: Wet weather4-day window: Wet weather
| Date | Rainfall | |
|---|---|---|
| 02/05/2026 (spill day) | 12.2 mm | rain |
| 01/05/2026 | 0.3 mm | rain |
| 30/04/2026 | 0.1 mm | dry |
| 29/04/2026 | 0 mm | dry |
| 28/04/2026 | 0 mm | dry |
River flow that day: 1.898 m³/s. Verify at the EA rainfall station.
Gauge proximity
Outlet (red) vs matched rain gauge (blue), 1.4 km apart. Closer means the rainfall reading is more representative of the overflow.
Loading map…
Severity & context
- Bathing water
- Not Applicable
- Shellfish water
- Teign Estuary
- Ahead of the works
- Yes — the treatment works' own overflow stayed shut that day, so capacity was available. Avoidable.
Method & provenance. Dry/wet classification is decided by rainfall at the nearest EA gauge — ≤ 0.25 mm on the spill day and each preceding day of the window (how we classify). Spill data: Environment Agency EDM (outlet SBB00301). Rainfall: EA Hydrology gauge e7e2f7d4-f497-4adc-b077-c20bc2dcedfa. A dry spill is precautionary evidence of a likely fault, not proof of an offence — we test the rainfall, not the works' flow. Generated by River Teign Data.